  •  19270 combo tester x3 with dual foot plate tests Operator’s Path-To-Ground; Wrist Strap Limits 750 kilohms to 10 megohms, Footwear Limits 750 kilohms to 35 megohms1
    Determines that operator’s personal grounding devices (wrist straps2, foot grounders, ESD shoes, smocks3) are functioning correctly.
  • Simultaneous Testing of Wrist Strap and Footwear in Less Than 3 Seconds
    Reduces time spent testing personal grounding devices used in ESD Control Plans
  • Solid-State Test Switch with No Moving Parts
    Maintains accuracy of tests and extends the lifetime of the tester
  • Split Foot Plate for Testing Foot Grounders (or ESD Shoes)
    Tests both foot grounders independently at the same time
  • 30 Volt Test Signal
    Provides accurate tests that are not humidity dependent
  • Relay for Use with Automatic Doors or Other Locking Systems
    Controls access to ESD Protected Areas
  • Optional Stand
    Use the Desco 19272 stand as an alternate installation method for the Combo Tester X3
  • Compatibility with ESD Glove Test Fixture
    Pair with the EMIT 50755 ESD Glove Test Fixture to allow operators to perform tests while wearing gloves or finger cots
  • Calibration Verification
    Use the EMIT 50424 Limit Comparator to check the test limits of the Combo Tester X3 without removing it from the workplace
  • NIST Calibrated with Certificated Included
    Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology. For more information on the calibration of Desco products, see Calibration.
  • 100-240VAC Power Adapter with Interchangeable Plugs
    Works with standard electrical systems in North America, United Kingdom, Japan, Asia and Europe
  • Made in the United States of America
    This item is made and stocked in Chino, CA

 


Related products

19271 COMBO TESTER X3 WITH STAND

19271 Combo Tester X3, With Stand Operator’s Path-To-Ground; Wrist Strap Limits 750 kilohms to 10 megohms, Footwear Limits 750 kilohms to 35 megohms1

19290 DIGITAL SURFACE RESISTANCE METER KIT

Features And Benefits The best balancing ionizer available Offset voltage balance controlled to ±3 Volts typical tested per...

ZERO VOLT BENCHTOP IONIZER

50690 Zero Volt Benchtop Ionizer. Single fan steady-state dc ionizer for 16” x 24” coverage area, Sealed plenum air flow

FAN IONIZER OVERHEAD ZERO VOLT

FAN IONIZER OVERHEAD ZERO VOLT with 3-Fan Overhead Ionizer, Fast Decay Times (< 3 seconds at 18”) and ±3 Volt Offset Voltage Balance...

Sign Up To Get Latest Updates

Follow by Email
Facebook
LinkedIn